Product Details:
|
Place Of Origin: | China | Brand Name: | Rainbow |
---|---|---|---|
Model Number: | ECG-8812 | Power Source: | Electric |
Warranty: | 1 Year | After-sale Service: | Online Technical Support |
Material: | Plastic | Shelf Life: | 2 Years |
Quality Certification: | Ce | Color: | White |
Application: | Hospital , Clinic | Feature: | Portable |
Function: | ECG Test | Categories: | Medical Equipment |
MOQ: | 1PCS | Weight: | 3.6Kg |
Highlight: | 7 Inch EKG Cardiograph Machine,12 Channel EKG Cardiograph Machine,PC ECG Software ECG Machine |
The intended use of the 12-Channel Electrocardiograph is to acquire ECG signals from adult patients through body surface ECG electrodes. The electrocardiograph is intended to be used only in hospitals or healthcare facilities by doctors and trained healthcare professionals. The cardiogram recorded by the 12-Channel Electrocardiograph can help users to analyze and diagnose heart disease. However the ECG with measurements and interpretive statements is offered to clinicians on an advisory basis only.
Features
♦ Digital signal processor for effective inhibition of baseline drift, AC interference filter, EMG interference filter and the heart rate, to guarantee the authenticity and dependability.
♦ Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.
♦ Have regular automatically measuring and analyzing function for ECG parameters to lessen doctor's load.
♦ With a high -resolution thermal printer to print out ECG trace, describing the trace clear and accurate, annotation as well as related parameters for diagnostic reference.
♦ Roll recording paper for ECG is 80mm in width, simultaneous 12 lead acquisitions and 3 lead live record, high affectivity of ECG examination, good effect and economic utility.
♦ Function of rhythm lead for observing abnormal ECG trace & heart rate.
♦ Supported by AC/Rechargeable battery for continuous examination whenever necessary. For Battery operation, ECG is equipped with a battery charger and a system for battery capacity management and protection.
♦ Safety level for ECG corresponds to Type CF, ClassII according to the IEC60601-1 criterion. The amplifier is floating input circuit which can examine human cordis directly with safety and reliability
ECG measurement
Lead: Standard 12 leads
Sampling mode: Simult
Sampling rate: 1000Hz
A/D Converter: 24bits
Frequency response: 0.05 ~ 160Hz (-3db)
Operation mode: Manual, Auto, Rhythm, 1 channel 1 minute
Filter: AC Filter: 50 Hz / 60Hz
EMG Filter: 25 Hz / 35 Hz / 45Hz/75 Hz / 100 Hz / 150Hz
DFT filter: 0.05Hz/0.5Hz
CMRR: >100dB (add AC filter)
Input mode: Floating and defibrillation protection
Input Impedance: > 50MQ (10Hz)
Input circuit current: <0.05MA
Input dynamic range: ‡10mVp-p
Patient leak current: < 10 A
Calibration voltage: 1mV+2%
Polarizing voltage: > ‡300mV
Time constant: ≥3.25
Paper specification: 210mm (W)#30m(L)
Recording mode: Thermal printing system
Noise level:
< 15 Vp-p
Memory 1000 cases
Threshold: <20₽V
Wave Gain/Sensitivity: 2.5mm/mV, 5mm/mV, 10mm/mV.
20mm/mV (standard sensitivity: 10mm/mV)
Wave/ Paper speed: 12.5mm/s,25mm/s,50mm/ (‡3%)
Machine Dimension: 365.4*323*85 mm
Weight: 2600g (not including the paper)
AC: 100V-240V(50/60Hz)
DC: 14.4V, 2500mAh, 36.00Wh
(Built-in rechargeable Li-ion battery)
Name of components
Accessory List
In order to obtain a good ECG trace,you are required to use the accompanying accessories of this unit. Following is the demonstration of the standard accessories for the unit.
Item | Quantity | |
1 | Patient Cable | 1 |
2 | Limb Electrode | 4pcs/set |
3 | Chest Electrode | 6pcs/set |
4 | Thermal Recording Paper | 1 |
5 | Paper Shaft | 1 |
6 | Three plugged power cable |
1 |
Contact Person: Lily